True to this slogan, RETEC
GmbH has developed a sensor for the pharmaceutical industry which
can be connected to any SPS. It requires a mere 18-30 V DC, the output
signal is a positive impulse (PNP). The installation is as simple as
possible. The sensor bridge is fitted vibration-free directly via the
product current to be measured. The fitting location should be prior to
labeling to avoid the label covering the range of the filling level to
be measured. The sensor unit detects and analyses the packing drum to be
tested without the need for any settings
If
no SPS is available, an evaluation unit can also be supplied.
The evaluation unit has counters for the number of tests as well
as for "badly" controlled objects. Corresponding alarm
outputs are also available, which can be further processed
externally. Alternatively, it is possible to output a serial
fault. This will be triggered after a selectable number of
serial faults. The only user setting required is to set the
sensor unit to the right "filling level" (in
accordance with the marking on the sensor).
|